Adobe Campaign Classic Flaw CVE-2026-105781: Update Now
Published October 29, 2026 · Last updated October 29, 2026
The short version: CVE-2026-105781 is a critical-severity security flaw in Adobe Campaign Classic. The National Vulnerability Database (NVD) published it on October 27, 2026, and the score it lists is 10.0 out of 10. When FraudMeNot checked on October 29, 2026, CISA had not added CVE-2026-105781 to its Known Exploited Vulnerabilities catalog, so there was no public U.S. government confirmation of attacks yet. A fix is available, which is why this page focuses on who should update and how.
What the official record says about CVE-2026-105781
The record was filed by adobe.com. In its own words: "Adobe Campaign Classic (ACC) is affected by an Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability that could result in arbitrary code execution in the context of the current user. An attacker could exploit this vulnerability to execute arbitrary SQL commands, potentially gaining elevated access or control over the victim's account or session. Exploitation of this issue does not require user interaction. Scope is changed."
Why Adobe Campaign Classic admins should care
Severity scores use the Common Vulnerability Scoring System (CVSS). the address listed on adobe.com rated CVE-2026-105781 10.0 (Critical) under CVSS 3.1. Reading that rating in everyday terms: it can be reached over a network, including the internet; an attacker does not need an account; no one has to click or open anything. If it is abused, the rated damage to keeping data private is high, to keeping data unaltered is high, and to keeping Adobe Campaign Classic running is high. Scoring string: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H.
Affected Adobe Campaign Classic releases
According to the record, these releases are vulnerable:
- 0 through 7.4.4 build 9402
The type of bug behind CVE-2026-105781
NVD classifies it using MITRE's Common Weakness Enumeration:
- CWE-89, Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection'). MITRE describes this class of bug as follows: "The product constructs all or part of an SQL command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended SQL command when it is sent to a downstream component. Without sufficient removal or quoting of SQL syntax in user-controllable inputs, the generated SQL query can cause those inputs to be interpreted as SQL instead of ordinary user data."
Vendor remediation for CVE-2026-105781
The vendor advisory remediation for operators of Adobe Campaign Classic, quoted for this page, is: "Install the Adobe Campaign Classic build listed in Adobe security bulletin APSB26-162, which also fixes the related flaws CVE-2026-104351, CVE-2026-104353, CVE-2026-105779 and CVE-2026-105780. Adobe-hosted (managed) customers should confirm with Adobe that their instance has been upgraded."
What to do about it
- Update now: Install the Adobe Campaign Classic build listed in Adobe security bulletin APSB26-162, which also fixes the related flaws CVE-2026-104351, CVE-2026-104353, CVE-2026-105779 and CVE-2026-105780. Adobe-hosted (managed) customers should confirm with Adobe that their instance has been upgraded.
- Who should act: IT teams, managed service providers, and developers who run or ship Adobe Campaign Classic. Check every place it runs, including servers, build systems, containers, and older machines nobody watches closely.
- Read the official advisory from Adobe (linked under Sources) for exact fixed builds and any temporary workaround if you cannot patch today.
- After patching, confirm the new version is actually running and review logs from October 27, 2026 onward for anything unusual.
- Home users: you do not need to buy or download anything because of CVE-2026-105781. A caller, text, or pop-up claiming your computer is "infected" with this CVE and asking for money or remote access is a scam.
CVE-2026-105781 record details from CISA and NVD
- Attack complexity for CVE-2026-105781: low
- CVE-2026-105781 CVSS scope: changed
- NVD sub-scores for CVE-2026-105781: exploitability 3.9, impact 6.0.
- Who mapped the weakness type: the address listed on adobe.com (Primary)
- References in the NVD record: 1.
Dates to know
- October 27, 2026: NVD publishes CVE-2026-105781.
- October 29, 2026: FraudMeNot checks the CISA KEV catalog; CVE-2026-105781 is not listed.
- October 28, 2026: most recent NVD update (record status: Awaiting Analysis).
Official references
Links listed in the NVD record (labels in brackets come from NVD):
Sources
General education only, not security advice. Facts checked against the sources above on the date shown.